SC
The SC series of sample coolers provide high cooling efficiency, being most suitable for most liquid, gas or vapor phase applications.

Refillable Cation Exchange Resin Columns

CR-600 & CR-1600
The function of the cationic resin columns is the removal by exchange of all the cations contained in a sample that come mainly from the dosage of some compound. The most commonly removed cations are the NH4 + from the amine dosage.

Degassed for degassed cationic conductivity measurement

DG-50
The degassed DG-50, is a device designed to degas the sample to be analyzed in water-steam cycles, eliminating dissolved gases, especially CO2 and obtaining a measurement of degassed conductivity. This design occupies minimum space and allows the integration of degassed, degassed + cationic or degassed + cationic + specific measurements in the degassed itself.

Degassed with automatic temperature setting according to atmospheric pressure.

DG-105
The degassed DG-105, is a device designed to degas the sample to be analyzed in water-steam cycles, eliminating dissolved gases, especially CO2 and obtaining a measurement of degassed conductivity. The advanced design of the DG-105 temperature degasser, performs an automatic temperature setpoint according to the atmospheric pressure , thus rapidly obtaining the degassed conductivity measurement, since it is not required to reach boiling point.

Back Pressure Regulator/Relief Valve

BPR
The pressure regulating valve BPR is used in lines of sampling systems, before the input to the analyzers, providing a constant pressure and flow of input to the analyzers.

Thermal Shutoff Valve

VTS
In the event that the sample temperature rises above the operating temperature of 49 ° C (120 ° F), the VTS thermal actuator modulates the valve to close the inlet port and prevent damage to equipment and in the instrumentation.

High Pressure Reducing ”Rod-in-tube” Valve

HPRV
The HPRV High Pressure Reducing Valve is designed for high pressure lines in sample systems, with an inlet pressure of up to 350 barg.

Sample Sequencer (Multiplexer)

SQ
System to measure several samples through a single analyzer, differentiating the measurement of each sample with independent outputs.

Sample Chiller

TCU
The temperature control unit (TCU) is a water condenser cooling system, which is responsible for providing the appropriate temperature to the cooling water that is used as cooling fluid in the secondary coolers of the sample lines, in order to of obtaining a stable temperature thereof.

Conditioning Panel

CP
The Manvia sample conditioning compact panel is designed to condition any type of steam-water sample.

This compact pre-tubed assembly allows analyzing the sample under optimal conditions.